{"id":4302,"date":"2013-09-02T09:19:55","date_gmt":"2013-09-02T09:19:55","guid":{"rendered":"https:\/\/santosvieiralda.com\/?page_id=4302"},"modified":"2014-01-01T12:09:43","modified_gmt":"2014-01-01T12:09:43","slug":"instalacoes-fixas-de-combate-a-incendios","status":"publish","type":"page","link":"https:\/\/santosvieiralda.com\/?page_id=4302","title":{"rendered":"Instala\u00e7\u00f5es Fixas de Combate a Inc\u00eandios"},"content":{"rendered":"<div class=\"aq-template-wrapper aq_row\"><div class=\"aq_span4 clearfix aq-first\"><img loading=\"lazy\" class=\"aligncenter size-medium wp-image-5312\" alt=\"norma1\" src=\"http:\/\/santosvieiralda.com\/wp-content\/uploads\/2013\/09\/norma11-300x154.jpg\" width=\"300\" height=\"154\" srcset=\"https:\/\/santosvieiralda.com\/wp-content\/uploads\/2013\/09\/norma11-300x154.jpg 300w, https:\/\/santosvieiralda.com\/wp-content\/uploads\/2013\/09\/norma11.jpg 700w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div><div class=\"aq_span4 clearfix \"><img loading=\"lazy\" class=\"aligncenter size-medium wp-image-5313\" alt=\"norma2\" src=\"http:\/\/santosvieiralda.com\/wp-content\/uploads\/2013\/09\/norma21-300x154.jpg\" width=\"300\" height=\"154\" srcset=\"https:\/\/santosvieiralda.com\/wp-content\/uploads\/2013\/09\/norma21-300x154.jpg 300w, https:\/\/santosvieiralda.com\/wp-content\/uploads\/2013\/09\/norma21.jpg 700w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div><div class=\"aq_span4 clearfix \"><img loading=\"lazy\" class=\"aligncenter size-medium wp-image-5314\" alt=\"norma3\" src=\"http:\/\/santosvieiralda.com\/wp-content\/uploads\/2013\/09\/norma31-300x154.jpg\" width=\"300\" height=\"154\" srcset=\"https:\/\/santosvieiralda.com\/wp-content\/uploads\/2013\/09\/norma31-300x154.jpg 300w, https:\/\/santosvieiralda.com\/wp-content\/uploads\/2013\/09\/norma31.jpg 700w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/div><\/div>\n<p align=\"justify\"><strong>NP EN 671-1 <\/strong><br \/>\nInstala\u00e7\u00f5es fixas de combate a inc\u00eandio &#8211; Sistemas armados com mangueiras. Parte 1: bocas-de-inc\u00eandio armadas com mangueiras semi-r\u00edgidas<\/p>\n<p align=\"justify\"><strong>NP EN 671-2<\/strong><br \/>\nInstala\u00e7\u00f5es fixas de combate a inc\u00eandio &#8211; sistemas armados com mangueiras. Parte 2: bocas-de-inc\u00eandio armadas com mangueiras flex\u00edveis<\/p>\n<p align=\"justify\"><strong>NP EN 671-3<\/strong><br \/>\nInstala\u00e7\u00f5es fixas de combate a inc\u00eandio. Sistemas armados com mangueiras. Parte 3: Manuten\u00e7\u00e3o das bocas-de-inc\u00eandio armadas com mangueiras semi-r\u00edgidas e das bocas de inc\u00eandio armadas com mangueiras flex\u00edveis.<\/p>\n<p align=\"justify\"><strong>EN 694 <\/strong><br \/>\n<em>Fire-fighting hoses. Semi-rigid hoses for fixed systems. <\/em><\/p>\n<p align=\"justify\"><strong>EN 12094-1 <\/strong><br \/>\n<em>Fixed firefighting systems &#8211; Components for gas extinguishing systems &#8211; Part 1: Requirements and test methods for electrical automatic control and delay devices <\/em><\/p>\n<p align=\"justify\"><strong>EN 12094-2<br \/>\n<\/strong><em>Fixed firefighting systems &#8211; Components for gas extinguishing systems &#8211; Part 2: Requirements and test methods for non-electrical automatic control and delay devices<\/em><strong> <\/strong><\/p>\n<p align=\"justify\"><strong>EN 12094-3<br \/>\n<\/strong><em>Fixed firefighting systems &#8211; Components for gas extinguishing systems &#8211; Part 3: Requirements and test methods for manual triggering and stop devices<\/em><strong> <\/strong><\/p>\n<p align=\"justify\"><strong>EN 12094-4<br \/>\n<\/strong><em>Fixed firefighting systems &#8211; Components for gas extinguishing systems &#8211; Part 4: Requirements and test methods for container valve assemblies and their actuators<\/em><strong> <\/strong><\/p>\n<p align=\"justify\"><strong>EN 12094-5<br \/>\n<\/strong><em>Fixed firefighting systems &#8211; Components for gas extinguishing systems &#8211; Part 5: Requirements and test methods for high and low pressure selector valves and their actuators<\/em><strong> <\/strong><\/p>\n<p align=\"justify\"><strong>EN 12094-6<br \/>\n<\/strong><em>Fixed firefighting systems &#8211; Components for gas extinguishing systems &#8211; Part 6: Requirements and test methods for non-electrical disable devices<\/em><strong> <\/strong><\/p>\n<p align=\"justify\"><strong>EN 12094-7<br \/>\n<\/strong><em>Fixed firefighting systems &#8211; Components for gas extinguishing systems &#8211; Part 7: Requirements and test methods for nozzles for CO2 systems<\/em><strong> <\/strong><\/p>\n<p align=\"justify\"><strong>EN 12094-8<br \/>\n<\/strong><em>Fixed firefighting systems &#8211; Components for gas extinguishing systems &#8211; Part 8: Requirements and test methods for connectors<\/em><strong> <\/strong><\/p>\n<p align=\"justify\"><strong>EN 12094-9<br \/>\n<\/strong><em>Fixed firefighting systems &#8211; Components for gas extinguishing systems &#8211; Part 9: Requirements and <\/em><em>methods <\/em><em>test <\/em><strong>\u00a0<\/strong><em>for special fire detectors<\/em><\/p>\n<td><strong>EN 12094-10<\/strong><br \/>\n<em>Fixed firefighting systems &#8211; Components for gas extinguishing systems &#8211; Part 10: Requirements and test methods for pressure gauges and pressure switches <\/em><\/p>\n<p><strong>EN 12094-11<\/strong><br \/>\n<em>Fixed firefighting systems &#8211; Components for gas extinguishing systems &#8211; Part 11: Requirements and test methods for mechanical weighing devices<\/em><\/p>\n<p><strong>EN 12094-12 <\/strong><br \/>\n<em>Fixed firefighting systems &#8211; Components for gas extinguishing systems &#8211; Part 12: Requirements and test methods for pneumatic alarm devices <\/em><\/p>\n<p><strong>EN 12094-13<\/strong><br \/>\n<em>Fixed firefighting systems &#8211; Components for gas extinguishing systems &#8211; Part 13: Requirements and test methods for check valves and non-return valves <\/em><\/p>\n<p><strong>EN 12094-16<\/strong><br \/>\n<em>Fixed firefighting systems &#8211; Components for gas extinguishing systems &#8211; Part 16: Requirements and test methods for odorizing devices for CO2 low pressure systems<\/em><\/p>\n<p><strong>EN 12259-1<\/strong><br \/>\n<em>Fixed firefighting systems components for sprinkler and waterspray systems &#8211; Part 1: Sprinklers <\/em><\/p>\n<p><strong>EN 12259-2 <\/strong><br \/>\n<em>Fixed firefighting systems &#8211; Components for sprinkler and water spray systems &#8211; Part 2: Wet alarm valve assemblies<\/em><\/p>\n<p><strong>EN 12259-3 <\/strong><br \/>\n<em>Fixed firefighting systems &#8211; Components for sprinkler and water spray systems &#8211; Part 3: Dry alarm valve assemblies<\/em><\/p>\n<p><strong>EN 12259-4 <\/strong><br \/>\n<em>Fixed firefighting systems &#8211; Components for sprinkler and water spray systems &#8211; Part 4: Water motor alarms <\/em><\/p>\n<p><strong>EN 12259-5 <\/strong><br \/>\n<em>Fixed firefighting systems &#8211; Components for sprinkler and water spray systems &#8211; Part 5: Water flow detectors<\/em><\/p>\n<p><strong>EN 12416-1 <\/strong><br \/>\n<em>Fixed firefighting systems &#8211; Powder systems &#8211; Part 1: Requirements and test methods for components<\/em><\/p>\n<p><strong>EN 12416-2<\/strong><br \/>\n<em>Fixed firefighting systems &#8211; Powder systems &#8211; Part 2: Design, construction and maintenance<\/em><\/p>\n<p><strong>EN 12845<\/strong><br \/>\n<em>Fixed firefighting systems &#8211; Automatic sprinkler systems &#8211; Design, installation and maintenance <\/em><\/p>\n<p><strong>EN 13565-1 <\/strong><br \/>\n<em>Fixed firefighting systems &#8211; Foam systems &#8211; Part 1: Requirements and test methods for components<\/em><\/p>\n<p><strong>EN 13565-2<\/strong><br \/>\n<em>Fixed firefighting systems &#8211; Foam systems &#8211; Part 2: Design, construction and maintenance <\/em><\/p>\n<p><strong>EN 14710-1<\/strong><br \/>\n<em>Fire-fighting pumps. Fire-fighting centrifugal pumps without primer. <\/em><em>Part 1: Classification, general and safety requirements.<\/em><\/p>\n<p><strong>EN 14710-2<\/strong><br \/>\n<em>Fire-fighting pumps. Fire-fighting centrifugal pumps without primer. <\/em><em>Part 2: Verification of general and safety requirements.<\/em><\/p>\n<p><strong>NP EN 14339<\/strong><br \/>\nHidrantes de inc\u00eandio enterrados<\/p>\n<p><strong>NP EN 14384 <\/strong><br \/>\nMarcos de inc\u00eandio (Hidrantes de inc\u00eandio de coluna).<\/p>\n<p><strong>ISO 14520-1<\/strong><br \/>\n<em>Gaseous fire-extinguishing systems. Physical properties and system design. <\/em><em>Part 1: General requirements<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>NP EN 671-1 Instala\u00e7\u00f5es fixas de combate a inc\u00eandio &#8211; Sistemas armados com mangueiras. Parte 1: bocas-de-inc\u00eandio armadas com mangueiras semi-r\u00edgidas NP EN 671-2 Instala\u00e7\u00f5es fixas de combate a inc\u00eandio &#8211; sistemas armados com mangueiras. Parte 2: bocas-de-inc\u00eandio armadas com mangueiras flex\u00edveis NP EN 671-3 Instala\u00e7\u00f5es fixas de combate a inc\u00eandio. Sistemas armados com mangueiras. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","meta":[],"_links":{"self":[{"href":"https:\/\/santosvieiralda.com\/index.php?rest_route=\/wp\/v2\/pages\/4302"}],"collection":[{"href":"https:\/\/santosvieiralda.com\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/santosvieiralda.com\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/santosvieiralda.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/santosvieiralda.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=4302"}],"version-history":[{"count":4,"href":"https:\/\/santosvieiralda.com\/index.php?rest_route=\/wp\/v2\/pages\/4302\/revisions"}],"predecessor-version":[{"id":5323,"href":"https:\/\/santosvieiralda.com\/index.php?rest_route=\/wp\/v2\/pages\/4302\/revisions\/5323"}],"wp:attachment":[{"href":"https:\/\/santosvieiralda.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=4302"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}